在线一本码道高清

Current position: Home > First-class fire engineer > First-class fire engineer exam questions > First-class fire engineer simulated test questions

2020 Comprehensive Capability Test for First Class Fire Engineers

点击量: Release time: January 9, 2020 13:42:58 Source: Global Online School Traffic:

First-level fire engineer registration, examination, check time, free SMS reminder

area

    Get VerifiedBook Now

    Please fill in the picture verification code to get the SMS verification code

    Can't see clearly, change a picture

    Get SMS Verification Code for Free

    [Abstract] 2020 first-level fire engineer test preparation has begun. Global Network School has compiled the "2020 First-Class Fire Engineer Comprehensive Competency Basic Test" for you. More test preparation materials, simulated test questions, and real questions over the years, please continue to pay attention to Global Online School First class fire engineer exam channel!

    Related Recommendations: Summary of Basic Capabilities for First Class Fire Engineers in 2020

    1. Regarding the installation of the cable-type mechanical drive device, the following statement is incorrect ()

    A. Except for the necessary exposed part of the cable, it should be protected by internal and external anti-corrosion steel pipes.

    B. Universal guide pulley should be used at the turn of the cable

    C. The handle at the end of the cable should be set in a special protective box

    D. Cable casing and protection box should be firmly fixed

    Correct answer: B

    2. Regarding the installation of fire pump couplings, the following statements are incorrect ()

    A. The fire pump coupling of the sprinkler system should be provided with a permanent fixed sign that is different from the fire pump coupling of the fire hydrant system and has a zone sign.

    B. Underground fire pump couplings should be cast iron manhole covers with the “fire pump coupling” logo cast, and permanent fixed signs indicating their location should be provided nearby

    C. The installation of the wall fire pump coupling should meet the design requirements

    D. When the design is not required, the installation height from the ground should be 0.9m, and the clear distance from the door, window, hole, and hole on the wall should not be less than 1.2m, and it should not be installed below the glass curtain wall.

    Correct answer: D

    3. The following is incorrect about the layout of equipment rooms in civil buildings ()

    A. Fire pump room should not be arranged on the third floor or below

    B. The fire pump room should not be arranged on the underground floor where the height difference between the ground floor of the basement and the outdoor entrance is greater than 10m.

    C. The fire resistance rating of the fire control room, fire pump room and building attached to the civil building shall not be lower than Grade II

    D. Fuel-filled high-voltage capacitor oil switch can be set on the second floor underground

    Answer: C

    4. Regarding the installation of fire extinguishing agent storage devices, the following statement is wrong ()

    A. The pressure relief direction of the pressure relief device on the header should not face the operating surface

    B. The flow direction indicator of the check valve connecting the storage container and the header should point to the direction of medium flow

    C. The header should be fixed on the support and frame. Supports and frames should be fixed firmly and treated with anti-corrosion

    D. The outer surface of the header should be painted with blue paint

    Correct answer: D

    5. A commercial building adopts the performance-based design evaluation method, and the software is used to simulate RSET = 300s and ASET = 450s. The following statement is incorrect ().

    A. The designer can be evacuated safely

    B. Available evacuation time is 450s

    C. Safety margin Ts is 150s

    D. Evacuation time is 300s

    Answer: D

    6. It is unreasonable to debug the fire emergency broadcast equipment in the automatic fire alarm system ().

    A. Selectively broadcast all broadcast partitions in the fire control room in an automatic manner, and forcibly switch all shared speakers; emergency broadcasts should be output with maximum power.

    B. Carry out a full load test on the loudspeaker and the spare loudspeaker. The voice of the emergency broadcast should be clear.

    C. The fire emergency broadcasting equipment system connected to the linkage system is put into an automatic working state, and then the working condition of the emergency broadcasting is checked according to the designed logical relationship, and the system should broadcast according to the designed logical.

    D. Disconnect any speaker, and the working status of other speakers should not be affected.

    Correct answer: A

    7. When the fire extinguishing agent conveying pipe is connected by screw thread, the pipe should be mechanically cut; there must be no missing or broken lines in the screw thread; the sealing material of the screw connection should be evenly attached to the threaded part of the pipe. Into the pipeline; the root of the thread after installation should have () exposed threads; after connection, the outside of the connection should be cleaned and treated with anticorrosion

    A.1 ~ 2

    B.2 ~ 3

    C.3 ~ 4

    D.4 ~ 5

    Correct answer: B

    The editor reminds you to avoid missed 2020 exam registration, payment, eligibility review, etc., you can book SMS reminders for free

    ”页面进行下载学习。 Global Network Alumni Tips: The above is the "Basic Practice of Comprehensive Competence of First-Class Fire Engineers in 2020" organized by the Global Network School Fire Engineer Channel for you . Free Download "page for download learning.

    share to: Edit: Sun Qing

    Bind phone number

    In accordance with the requirements of the "Internet Security Law of the People's Republic of China" to strengthen the real-name authentication mechanism, and at the same time to provide a more comprehensive experience of product services, please bind your mobile phone number.

    Appointment made

    This live broadcast is a live lesson for paid students

    Please make a reservation after purchasing the course

    直播、听课。 Global classroom mobile classroom APP broadcast live, listen to lessons. Insta Future!

    Android version

    download

    iPhone version

    download
    Global Small Over-Global WeChat Official WeChat Service Platform

    Resolving problems APP download

    Free live one-click lessons

    Registration and other manual services

    Back to top